Physics / Resistance vs. Temperature
FREE TO EXPLORE
EXPERIMENT 48 · PHYSICS LABORATORY

Resistance vs. Temperature lab report

A worked resistance vs. temperature lab report with simulated observation tables, graph, calculations, uncertainty and results.

WORKED EXAMPLE · SIMULATED OBSERVATIONS

A complete example report.

Simulated demonstration data.

This report shows the method and arithmetic. It is not evidence of a physical experiment. Replace its observations with your own measurements when preparing a real lab report.

Student: __________________Student ID: __________________Course: __________________Date: __________________Partner: __________________Instructor: __________________

1. Title and aim

The Dependence of Resistance on Temperature: Temperature Coefficient of Resistance of Copper. To investigate the variation of electrical resistance of a metallic copper conductor as a function of temperature, determine its temperature coefficient of resistance (α) and reference resistance at 0 °C (R₀) via linear regression, and extrapolate the inferred absolute zero of resistance.

2. Abstract

Five observations were generated from the ideal teaching model over the settings listed below. A straight-line fit gave an estimate of temperature coefficient of resistance of 3.930 × 10⁻³ °C⁻¹, differing by 0.000% from the model value. The reported scatter comes from scale rounding and any stated model approximation, not measured laboratory noise.

3. Apparatus and fixed settings

4. Theory and graph choice

The electrical resistance of pure metallic conductors varies directly with temperature as a consequence of electron-phonon scattering. At temperatures above absolute zero, thermal vibrations of lattice ions increase in amplitude, presenting a larger scattering cross-section to conduction electrons and shortening their mean collision time. Over normal operating ranges (0 °C to 100 °C), this relationship is highly linear: R(T) = R₀(1 + α T). By measuring the resistance of a calibrated copper coil immersed in a thermostatically controlled bath across multiple temperatures and applying linear regression, students determine the baseline ice-point resistance R₀ from the intercept, the temperature coefficient of resistance α from the ratio of slope to intercept, and extrapolate the inferred absolute zero of electrical resistance.

R = (R₀ α) · T + R₀; α = m / b, R₀ = b

The calculation fits y = mx + b in SI units. The graph may display scaled axes for readability; those display factors are removed before calculating the physical result. The gradient has units Ω °C⁻¹.

5. Method

  1. Immerse the copper coil sheath and calibrated mercury thermometer into a vigorously stirred equilibrium mixture of crushed distilled ice and pure water at 0.0 °C. Connect the four terminals of the digital bridge (two current leads, two potential leads) to the coil binding posts. Wait 5 minutes for complete thermal equilibrium and record the ice-point baseline resistance R₀ = 100.00 Ω.
  2. Transfer the coil and thermometer into the thermostatically controlled heating bath filled with distilled water. Activate the motorized circulation stirrer at moderate speed to ensure vigorous convective fluid mixing throughout the tank, eliminating vertical temperature stratification.
  3. Energize the immersion heater to elevate the bath temperature to approximately 20.0 °C. Throttle the heater power and monitor the thermometer until the temperature stabilizes to within ±0.1 °C for at least 60 seconds, ensuring that the internal copper windings have reached isothermal steady state with the bath.
  4. Record the stabilized bath temperature T (in °C) and the corresponding four-wire resistance reading R (in Ω). Re-energize the heater to raise the bath temperature sequentially to 40.0 °C, 60.0 °C, 80.0 °C, and 100.0 °C (boiling point), recording the equilibrium resistance at each station.
  5. Tabulate the paired observations of temperature T (horizontal axis x) and coil resistance R (vertical axis y). Compute the ordinary least-squares linear regression coefficients to determine the slope m = ΔR/ΔT (in Ω °C⁻¹) and the vertical intercept b (in Ω).
  6. Calculate the temperature coefficient of resistance as α = m / b. Compute the inferred absolute zero of electrical resistance by extrapolating the best-fit line to R = 0 (T_abs = −b / m = −1 / α), and compare the experimental values against standard copper reference tables.

6. Observations and calculation table

All observations use fixed model settings. Values are rounded only at the instrument reading stage; further calculations use full precision. Repeated physical trials are not claimed.

Table 1. Five simulated measurements; x and y are in SI units.
No.Bath temperature T (°C)Coil resistance R (Ω)x (SI)y (SI)Fitted y (SI)Residual (SI)
10.0100.000.00000100.00000100.00000-1.4211e-14
220.0107.8620.00000107.86000107.86000-1.4211e-14
340.0115.7240.00000115.72000115.72000-1.4211e-14
460.0123.5860.00000123.58000123.58000-1.4211e-14
580.0131.4480.00000131.44000131.44000-2.8422e-14
6100.0139.30100.00000139.30000139.300000.00000

Download the sample observations (CSV) ↓

7. Worked calculation for one observation

Bath temperature T = 0.0 °C; observed coil resistance R = 100.00 Ω; baseline ice-point resistance R₀ = 100.00 Ω. Single-station temperature coefficient estimate α_single = (R − R₀) / (R₀ · T) = (100.00 − 100.00) / (100.00 × 0.0) = 0.003930 °C⁻¹ (3.930 × 10⁻³ °C⁻¹). Linear regression of R against T across all six temperature stations yields the reported slope S = R₀ α and intercept b = R₀.

8. Graph, gradient and final calculation

96.07-10.00107.8620.00119.6550.00131.4480.00143.23110.00Temperature T (°C)Resistance R (Ω)

Dots show the sample observations. The line is the ordinary least-squares fit.

x̄ = 50.00000; ȳ = 119.65000
Σ(x − x̄)² = 7000.00000
Σ(x − x̄)(y − ȳ) = 2751.00000
m = Σ(x − x̄)(y − ȳ) / Σ(x − x̄)² = 0.39300000
b = ȳ − mx̄ = 100.00000000
Slope S = 0.393000 Ω °C⁻¹; Intercept b = R₀ = 100.000 Ω; Temperature coefficient α = S / b = 0.0039300 °C⁻¹ (3.9300 × 10⁻³ °C⁻¹); Inferred absolute zero T_abs = −b / S = -254.45 °C (theoretical: −254.5 °C)

9. Uncertainty and comparison

Percentage difference = |estimate − model value| / |model value| × 100 = 0.0000%. Percentage difference is not experimental uncertainty.

For n = 5 observations, Σresidual² = 1.2117e-27; s² = Σresidual²/(n − 2). Gradient standard error = √[s²/Σ(x − x̄)²] = 2.0803e-16. Intercept standard error = √[s²(1/n + x̄²/Σ(x − x̄)²)] = 1.2597e-14.

Propagating only the relevant fit coefficient gives a fit-only standard error of 2.0803e-15 × 10⁻³ °C⁻¹. This is a one-standard-error quantity under the regression assumptions. Deterministic rounded model data do not supply a complete physical uncertainty budget.

Thermodynamic thermal lag between the protective brass sheath and the internal copper wire windings (minimized by maintaining steady temperature holding times ≥ 60 s before each reading), fluid bath thermal stratification and convective layering (eliminated by continuous motorized paddle circulation), digital bridge Joule self-heating (kept below 0.002 °C by restricting test excitation current to I_test ≤ 1.0 mA), partial-immersion mercury stem emergence cooling correction (ΔT_stem = 0.00016 · n · (T − T_ambient) ≈ 0.04 °C at 100 °C), lead wire and terminal contact resistance offsets (completely bypassed via four-terminal Kelvin 4-wire sensing), and secondary non-linear Callendar-Van Dusen curvature (< 0.05% below 100 °C) govern the uncertainty envelope. Ordinary least-squares regression of coil resistance R against temperature T averages out thermometer meniscus parallax and digital bridge quantization fluctuations, with the slope isolating the pure thermal rate of change dR/dT and the vertical intercept isolating the true ice-point baseline resistance R₀.

10. Result and discussion

α = 3.930 × 10⁻³ °C⁻¹ = 3.930 × 10⁻³ °C⁻¹
Model comparison value: 3.930 × 10⁻³ °C⁻¹

The observations follow the stated model relationship. Check whether the intercept and residual pattern suggest a systematic offset or a missing approximation. Agreement with the model does not independently verify its input constants.

11. Precautions and limitations

Calculations assume uniform thermal equilibrium between the bath and copper winding, negligible Joule self-heating (excitation current ≤ 1 mA), and neglect higher-order quadratic Callendar-Van Dusen curvature which contributes < 0.05% below 100 °C. Real copper specimens exhibit slight residual resistance at cryogenic temperatures (Matthiessen's rule: ρ = ρ_residual + ρ_phonon(T)), while industrial platinum RTDs incorporate small second-order coefficients (B ≈ −5.775 × 10⁻⁷ °C⁻²).

12. Conclusion

The worked example illustrates how to obtain temperature coefficient of resistance from measurements, graph variables and a fitted coefficient. The estimate is 3.930 × 10⁻³ °C⁻¹. A real experiment must additionally evaluate the apparatus-specific uncertainties and corrections described above.