EXPERIMENT 50 · PHYSICS LABORATORY
The Heat Equivalent of Electrical Energy: Joule's Law of Electrical Heating
To determine the electrical and mechanical equivalent of heat (Joule's constant J) by electrical calorimeter heating, verify Joule's law of electric power dissipation (W = V I t), and evaluate radiation cooling corrections. Explore a virtual apparatus, collect readings and analyse a graph.
FOLLOW THE METHOD
A reason behind every step.
To determine the electrical and mechanical equivalent of heat (Joule's constant J) by electrical calorimeter heating, verify Joule's law of electric power dissipation (W = V I t), and evaluate radiation cooling corrections. Suggested independent settings: 120.0, 240.0, 360.0, 480.0, 600.0, 720.0 s.
1Calorimeter Preparation and Water Mass Measurement
Weigh the clean, dry inner copper calorimeter vessel on a balance, add exactly 250.0 g of distilled water, and re-weigh to verify total mass. Place the inner vessel inside the outer insulating air jacket, seat the phenolic lid, and insert the immersion heating coil, motorized stirrer, and fractional-degree thermometer.
Why this step matters
Accurate initial water mass is required to compute the baseline system heat capacity C_sys = m_w c_w + W_eq.
2Thermal Equilibrium and Baseline Temperature Verification
Activate the motorized stirrer at gentle speed and allow the calorimeter system 5 minutes to reach thermal equilibrium with the ambient laboratory. Read and record the initial quiescent temperature T₀ = 20.00 °C on the fractional-degree thermometer.
Why this step matters
Starting from stable ambient room temperature minimizes initial convective heat exchange before electrical energy is introduced.
3Electrical Circuit Assembly and Wattage Calibration
Connect the regulated DC power supply in series with the ammeter and immersion heating coil. Connect the digital voltmeter directly across the coil terminal posts (four-wire Kelvin sensing) to exclude lead resistance drops. Energize the supply momentarily to set V = 10.00 V and I = 2.500 A (P = 25.00 W), then open the main switch.
Why this step matters
Kelvin voltage sensing across the coil terminals ensures that only the electrical power dissipated inside the water is integrated into the work calculation.
4Timed Electrical Heating and Continuous Stirring
Simultaneously close the power switch and start the digital chronometer. Maintain continuous gentle stirring while monitoring the voltmeter and ammeter to verify constant power delivery. Run the heating for an initial duration of 120.0 s (2.0 min, delivering W = 3000 J), open the switch, and continue stirring until the thermometer reaches its maximum stabilized reading T.
Why this step matters
Stirring after switching off ensures that all thermal energy stored in the heating wire sheath diffuses into the water before reading peak temperature.
5Sequential Heating Runs Across Increasing Energy Levels
Repeat the timed heating runs for cumulative durations of 240.0 s (6000 J), 360.0 s (9000 J), 480.0 s (12000 J), 600.0 s (15000 J), and 720.0 s (18000 J), recording the peak stabilized temperature T at each duration. Compute the temperature rise ΔT = T − T₀ and the corresponding heat absorbed Q = C_sys · ΔT in calories.
Why this step matters
Sampling six evenly spaced durations spanning 3000 J to 18000 J provides wide leverage for linear regression analysis.
6Linear Regression and Joule Constant Extraction
Plot heat absorbed Q (in calories) on the horizontal axis and electrical energy W = V · I · t (in Joules) on the vertical axis. Compute ordinary least-squares linear regression to determine the slope J = ΔW / ΔQ (in J/cal) and the vertical intercept b. Calculate the heat equivalent of electrical energy a = 1 / J (in cal/J) and compare against standard reference values.
Why this step matters
Linear regression averages out thermometer quantization and minor radiation losses, isolating the pure conversion factor between electrical work and thermal energy.