Pilot Vertical Climbing-Film Tubular Evaporator
Stainless steel calandria tube (ID 25.4 mm, length 2.0 m, area 0.160 m^2) with external steam jacket.
Operate a pilot-scale single-effect vertical climbing/falling-film evaporator concentrating aqueous sucrose solution, evaluate water evaporation rate and steam economy as a function of heating steam pressure, and determine overall heat transfer coefficient U_evap. Explore interactive transport phenomena, unit operations simulation, and chemical engineering telemetry.
Ready to sample with Steam Press P_s = 1.5 bar.
Adjust Steam Press P_s, then execute chemical process trial.
Chemical and process engineering telemetry is evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity transport phenomena and unit operations modeling.
The transport and thermodynamic models apply within the specified calibrated operating window (0.5 to 3.0 bar). Evaluated using a single-tube vertical climbing-film evaporator (tube ID 25.4 mm, length 2.0 m, area A = 0.160 m^2) operating at atmospheric boiling pressure (T_boil = 100.5 °C). Linear regression models evaporation rate m_dot_v versus steam gauge pressure P_s.
Stainless steel calandria tube (ID 25.4 mm, length 2.0 m, area 0.160 m^2) with external steam jacket.
Separates concentrated liquid liquor from evaporated steam vapor with zero liquid droplet entrainment.
Condenses evaporated water vapor into a graduated distillate condensate catch vessel.
Captures condensed heating steam to measure steam consumption rate m_dot_s.
Maintains saturated steam supply pressure stable from 0.5 to 3.0 bar gauge.
Measures Brix sucrose concentration of feed and concentrated bottom liquor with 0.1% accuracy.
Operate a pilot-scale single-effect vertical climbing/falling-film evaporator concentrating aqueous sucrose solution, evaluate water evaporation rate and steam economy as a function of heating steam pressure, and determine overall heat transfer coefficient U_evap. Standardized parameter settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 bar.
Crack open the steam supply valve to purge non-condensable air and warm the calandria; verify steam trap discharges condensate freely.
Pump 10.0 wt% sucrose feed solution into the bottom calandria tube at 20.0 L/h; adjust liquid level to one-third tube height.
Set steam jacket pressure regulator to P_s = 0.5 bar gauge (T_s = 111.4 °C); observe development of two-phase climbing film.
Allow 15 minutes of steady evaporation; collect overhead distillate condensate m_dot_v and heating steam condensate m_dot_s over a 10-minute interval.
Increment steam gauge pressure through 1.0, 1.5, 2.0, 2.5, and 3.0 bar, recording distillate production, steam consumption, and liquor Brix at each plateau.
Plot water evaporation rate m_dot_v versus steam pressure P_s, fit a linear regression through the origin, and calculate steam economy SE.
Points are your recorded observations. The solid regression line validates Tubular Evaporator Steam Economy mathematical scaling.
| # | Steam Jacket Gauge Pressure P_s (bar) | Vapor Evaporation Rate m_dot_v (kg/h) | Heating steam gauge pressure P_s (bar) | Water evaporation rate m_dot_v (kg/h) | Remove |
|---|
No readings yet. Execute a process trial and record it.
Evaporation is a major thermal separation unit operation in chemical processing, pulp and paper, desalination, and sugar manufacturing, responsible for concentrating dilute aqueous solutions by boiling off volatile water solvent. A single-effect tubular evaporator comprises a vertical shell-and-tube calandria where condensing utility steam outside the tubes transfers latent heat across the metal wall into the process liquid boiling inside the tubes. As vapor is generated, rising vapor bubbles expand rapidly, accelerating the liquid upward in climbing-film annular flow or descending as a thin turbulent falling film. Key performance metrics include the water evaporation mass rate m_dot_v, the overall heat transfer coefficient U_evap, and the dimensionless steam economy SE, defined as kilograms of water evaporated per kilogram of heating steam consumed: SE = m_dot_v / m_dot_s. For a single-effect unit without vapor recompression, steam economy is fundamentally limited to less than 1.0 (typically 0.80 to 0.95) due to radiation losses, feed preheating, and boiling point elevation (BPE) caused by non-volatile solutes. Increasing steam jacket pressure P_s elevates steam saturation temperature T_s, widening the thermal driving force (T_s - T_boil) and proportionally accelerating the evaporation rate: m_dot_v = S · P_s. In this experiment, a pilot climbing-film evaporator concentrating a 10 wt% sucrose feed is operated across steam pressures from 0.5 to 3.0 bar to evaluate evaporation rate sensitivity S and measure steam economy.
Evaluated using a single-tube vertical climbing-film evaporator (tube ID 25.4 mm, length 2.0 m, area A = 0.160 m^2) operating at atmospheric boiling pressure (T_boil = 100.5 °C). Linear regression models evaporation rate m_dot_v versus steam gauge pressure P_s.