Power-Compensation Isothermal Titration Calorimeter (ITC)
Maintains sample cell at 25.0000 °C using active thermoelectric feedback, measuring heat pulses down to 0.1 μJ.
Operate a power-compensation isothermal titration calorimeter (ITC) at 25.000 °C to measure the heat of mixing during incremental microliter injections of ethanol into water across composition factors x_1·(1 - x_1) from 0.05 to 0.25, evaluate the molar excess enthalpy H^E, and determine the Redlich–Kister excess enthalpy parameter A_0. Explore interactive transport phenomena, unit operations simulation, and chemical engineering telemetry.
Ready to sample with Composition Factor x_1·x_2 = 0.13 dimensionless.
Adjust Composition Factor x_1·x_2, then execute chemical process trial.
Chemical and process engineering telemetry is evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity transport phenomena and unit operations modeling.
The transport and thermodynamic models apply within the specified calibrated operating window (0.05 to 0.25 dimensionless). Evaluated using a MicroCal PEAQ-ITC power-compensation isothermal titration calorimeter with 1.40 mL Hastelloy cell, 250 μL injection syringe, and active Peltier feedback control (±0.0001 °C). Calibrated against standard water-water dilution blank and 2-propanol/water heat-of-mixing standards.
Maintains sample cell at 25.0000 °C using active thermoelectric feedback, measuring heat pulses down to 0.1 μJ.
Resists chemical corrosion and provides rapid thermal equilibration with surrounding heat sink.
Dispenses reproducible 10.0 μL liquid titrant pulses while stirring continuously at 750 RPM.
Establishes a steady reference temperature difference of 0.50 °C for power-compensation baseline.
Degasses all aqueous and organic feedstocks for 15 minutes to prevent injection bubble artifacts.
Verifies moisture content and exact gravimetric purity of feedstock absolute ethanol.
Operate a power-compensation isothermal titration calorimeter (ITC) at 25.000 °C to measure the heat of mixing during incremental microliter injections of ethanol into water across composition factors x_1·(1 - x_1) from 0.05 to 0.25, evaluate the molar excess enthalpy H^E, and determine the Redlich–Kister excess enthalpy parameter A_0. Standardized parameter settings: 0.05, 0.09, 0.13, 0.17, 0.21, 0.25 dimensionless.
Degas HPLC water and absolute ethanol under vacuum for 15 minutes; fill reference cell with degassed water and establish 25.000 °C baseline.
Load sample cell with 1.40 mL degassed pure water; fill automated injection syringe with 250 μL pure absolute ethanol, purging air bubbles.
Program ITC sequence for 20 successive injections of 10.0 μL with 150 s spacing at 750 RPM stirring speed.
Discard initial 0.4 μL pre-injection; initiate automated titration run, logging power compensation response curves (μcal/s) versus time.
Integrate power compensation peaks for each injection to determine differential heats of mixing dQ; calculate cumulative molar excess enthalpy H^E.
Plot molar excess enthalpy H^E versus composition factor x_1·(1 - x_1); fit linear regression through origin to extract A_0.
Points are your recorded observations. The solid regression line validates Excess Enthalpy of Mixing ITC mathematical scaling.
| # | Mixture Composition Product x_1·(1 - x_1) (dimensionless) | Measured Molar Excess Enthalpy H^E (J/mol) | Composition factor x_1·(1 - x_1) | Molar excess enthalpy H^E (J/mol) | Remove |
|---|
No readings yet. Execute a process trial and record it.
Excess enthalpy of mixing (H^E, also referred to as heat of mixing or excess enthalpy of solution) is a critical thermodynamic property in chemical engineering process design, heat exchanger sizing, reactor thermal management, and flash separation calculations. For an ideal solution, the enthalpy of mixing is strictly zero (ΔH_mix^ideal = 0), meaning mixing pure components at constant temperature and pressure releases or absorbs no heat. In real mixtures, however, breaking like-molecule intermolecular bonds (A-A and B-B) and creating unlike-molecule bonds (A-B) results in an energy imbalance. In the binary ethanol-water system, mixing is exothermic at ambient temperatures (H^E < 0) due to strong cross-association hydrogen bonding between water molecules and ethanol hydroxyl groups, releasing significant heat. The molar excess enthalpy is modeled using the Redlich–Kister polynomial expansion: H^E = x_1 · x_2 · [A_0 + A_1 · (x_1 - x_2) + A_2 · (x_1 - x_2)^2 + ...], where x_1 and x_2 = 1 - x_1 are mole fractions and A_k are temperature-dependent empirical interaction coefficients. In a symmetric first-approximation formulation, excess enthalpy scales directly with the product of the mole fractions: H^E = A_0 · [x_1 · (1 - x_1)], where A_0 is the leading Redlich–Kister parameter. Isothermal Titration Calorimetry (ITC) provides the highest precision method for measuring heats of mixing. Operating under active power-compensation feedback, the ITC sample cell (volume 1.40 mL) is maintained at strictly constant temperature (25.000 ± 0.0001 °C) while automated precision syringe injections (10.0 μL) deliver titrant into the stirred sample cell. Thermal compensation power pulses are integrated to quantify the enthalpy change of each injection with sub-microjoule resolution. In this laboratory experiment, an automated ITC unit measures the heat of mixing across composition products x_1·(1 - x_1) from 0.05 to 0.25 at 25.000 °C to determine the Redlich–Kister parameter A_0 = -3450.0000 J/mol.
Evaluated using a MicroCal PEAQ-ITC power-compensation isothermal titration calorimeter with 1.40 mL Hastelloy cell, 250 μL injection syringe, and active Peltier feedback control (±0.0001 °C). Calibrated against standard water-water dilution blank and 2-propanol/water heat-of-mixing standards.