Standard 6-Inch Throat Parshall Flume
Precision fabricated stainless steel flume with standardized converging, throat, and diverging sections.
Calibrate a standard Parshall flume in an open irrigation channel, determine the free-flow power-law discharge rating equation, and evaluate the critical submergence limit. Explore interactive farm machinery simulation, irrigation hydraulics, and agricultural engineering telemetry.
Ready to sample with ln(Head H_a) = -1.7429 ln(m).
Adjust ln(Head H_a), then execute agricultural trial.
Agricultural engineering telemetry and biosystems states are evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity agricultural and environmental modeling.
Flumes must be fabricated strictly to standardized ASTM/USBR dimensions; geometric scaling errors invalidate published discharge coefficients. Evaluated using a standard 6-inch (15.2 cm) throat width Parshall flume in free-flow regime across upstream heads from 0.05 m to 0.40 m.
Precision fabricated stainless steel flume with standardized converging, throat, and diverging sections.
Laboratory flume canal 60 cm wide and 10 m long with recirculating water pump and tailwater gate.
Measures upstream water depth H_a and throat depth H_b with 0.1 mm accuracy.
Supplies independent benchmark volumetric discharge rate Q with 0.5% precision.
Modulates downstream water level to test free-flow versus submerged-flow regimes.
Continuously records water surface elevation heads in the stilling wells.
Calibrate a standard Parshall flume in an open irrigation channel, determine the free-flow power-law discharge rating equation, and evaluate the critical submergence limit. Standardized parameter settings: -2.9957, -2.5257, -2.1203, -1.7148, -1.3093, -0.9163 ln(m).
Level the Parshall flume longitudinally and laterally in the channel. Set the stilling well point gauges to exactly zero against the flat crest of the flume converging floor.
Lower the downstream tailwater gate completely to ensure free-fall discharge, ensuring the submergence ratio H_b / H_a remains well below 0.60.
Regulate pump throttle to deliver initial low discharge producing an upstream head H_a = 0.05 m (ln H_a = -2.9957), allowing water levels in the stilling wells to stabilize.
Record the upstream head H_a from the stilling well and the reference discharge Q from the magnetic flowmeter simultaneously over 3 minutes.
Increment pump discharge in five uniform stages to achieve upstream heads of 0.08, 0.12, 0.18, 0.27, and 0.40 m, recording H_a and Q for each flow rate.
Transform H_a and Q into natural logarithms, plot ln Q versus ln H_a, and perform linear regression to determine the exponent n and coefficient C.
Points are your recorded observations. The solid regression line validates Parshall Flume Calibration mathematical scaling.
| # | Logarithm of Upstream Gauge Head ln(H_a) (ln(m)) | Logarithm of Discharge ln(Q) (ln(m³/s)) | ln(Upstream head H_a in m) | ln(Discharge Q in m³/s) | Remove |
|---|
No readings yet. Execute an agricultural trial and record it.