Cross-Fluted Cellulose Pad Test Section
Provides standard 100 mm thick corrugated pad media (1.0 m wide by 1.0 m high) with top distribution header.
Determine the cooling saturation efficiency and water evaporation rate of a cellulose wet-pad ventilation system under varying approach face air velocities. Explore interactive farm machinery simulation, irrigation hydraulics, and agricultural engineering telemetry.
Ready to sample with Face Velocity v = 1.1 m/s.
Adjust Face Velocity v, then execute agricultural trial.
Agricultural engineering telemetry and biosystems states are evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity agricultural and environmental modeling.
The linear evaporation model is valid for the design operational velocity range of 0.5 to 2.0 m/s. Evaluated on a 100 mm thick cross-fluted cellulose pad (flute angle 45°/15°) at standard ambient conditions (35.0 °C dry-bulb, 22.0 °C wet-bulb). Face air velocity is controlled between 0.5 and 2.0 m/s with uniform top-header water distribution.
Provides standard 100 mm thick corrugated pad media (1.0 m wide by 1.0 m high) with top distribution header.
Draws air through the wind tunnel to establish uniform face velocities from 0.5 to 2.0 m/s.
Measures upstream and downstream psychrometric states with calibrated precision thermistors.
Monitors net evaporative water consumption in real time with 1.0 gram gravimetric resolution.
Monitors pad wetting water flow rate to ensure complete wetting above the minimum dry-out threshold.
Measures static pressure drop across the cooling pad in Pascals.
Determine the cooling saturation efficiency and water evaporation rate of a cellulose wet-pad ventilation system under varying approach face air velocities. Standardized parameter settings: 0.5, 0.8, 1.1, 1.4, 1.7, 2.0 m/s.
Energize the recirculation pump for 20 minutes to thoroughly wet the cellulose pad until uniform water curtaining is established.
Set the exhaust fan frequency drive to produce an approach face velocity of 0.5 m/s measured via multi-point pitot tube array.
Operate the system for 10 minutes until downstream dry-bulb temperature reaches steady equilibrium.
Record upstream and downstream dry-bulb and wet-bulb temperatures and log water reservoir mass depletion over a 15-minute window.
Increment face air velocity to 0.8, 1.1, 1.4, 1.7, and 2.0 m/s, repeating gravimetric and psychrometric measurements at each stage.
Calculate cooling saturation efficiency η_c = (T_db,in - T_db,out)/(T_db,in - T_wb,in) and plot evaporation rate m_dot_w against face velocity v_pad.
Points are your recorded observations. The solid regression line validates Evaporative Pad Cooling mathematical scaling.
| # | Pad Face Air Velocity v_pad (m/s) | Water Evaporation Rate m_dot_w (g/(min·m²)) | Pad face velocity v_pad (m/s) | Evaporation rate m_dot_w (g/(min·m²)) | Remove |
|---|
No readings yet. Execute an agricultural trial and record it.